Oxygen Measurement



  1. Oxygen Measurement Instrument
  2. Measuring Oxygen Level
Sensors for measuring oxygen

Semiconductor Equipment
Crystec Technology Trading GmbH

Oxygen Measurement in Natural Gas. Application Background Natural Gas Fuel is primarily methane. If it were pure methane, it would be very simple to transport and use. But it comes out of the well as a mixture of many different chemicals, many of which are considered contaminants in this fuel. After ‘sweetening’ (removing the acidic. Blood cells are a bright red when they are loaded with oxygen, and they change to a bluish color when they are no longer carrying a full load of oxygen. The finger clip machine cannot give a perfect measurement of your oxygen saturation; it can give only a rough estimate, and its measurement can be affected by things as simple as red nail.

Oxygen measurement with an zirconium oxide sensor

Oxygen measurement

Zirconium oxide is the most common component of the element Zirconium. ZrO2 is an oxide ceramic or refractory, which crystallizes in 3 lattice structurs. By doping the zirconium dioxide with Yttria, defects or voids are introduced in the crystal lattice. In the solid zirconia, some Zr4+ ions are replaced by Y3+ ions so that oxygen vacancies are created which allow oxide anions O2-, especially at high tempertures over 650°C to diffuse fast in the solid crystal lattice. Yttrrium doped Zirconia is a solid electrolyte. This conductivity for oxygen anions is used for measuring oxygen by Zirconium oxide (ZrO2) high temperature electrochemical sensors, known also as hot probes.

  • As oxygen in the atmosphere is about 20.3%, the partial pressure of oxygen at sea level (1 atm) is 0.203 atm. Thus the amount of dissolved oxygen at 100% saturation at sea level at 20° C is 9.03 mg/L ¹⁰. The equation shows that water will remain at 100% air saturation at equilibrium. However, there are several factors that can affect this.
  • When you have an increased humidity level, you have an increased partial pressure of oxygen, and therefore you have an increased level of dissolved oxygen. How do we measure dissolved oxygen? We can measure dissolved oxygen through iodometry.

The oxygen measurement cell
In the measurement unit, a zirconium oxide membrane separates a reference gas (e.g. air) from the sample gas. Both sides of the membrane are coated with thin palladium films, which serve as electrodes so that a solid, electrochemical cell is formed. As long as the oxygen partial pressure is equal on both sides, the movement of oxygen ions within the membrane is random. When the oxygen concentration on both sides of the membran becomes different, then oxygen ions start migrating within the crystal lattice from the side of higher O2 partial pressure to the lower pressure side. A concentration gradient of oxygen ions is established in the ZrO2 lattice, which produces a voltage potential between the two platinum electrodes according to the Nernst Equation. The relationship between the voltage and the O2 partial pressure change in the gas sample is logarithmic. This methode can be used for measuring oxygen concentration in the percent-range as well as for oxygen trace measurements (ppm). Zirconium oxide oxygen analyzers have fast speed of response. It needs to be considered that already the presence of small amounts of reducing gases will disturb the trace measurement.

Due to the high operating temperature, zirconium oxide sensors can be used for measuring oxygen O2 in a furnace / in furnaces like vertical furnaces, horizontal furnace, conveyer furnaces, box ovens and industrial furnaces.

Stange O2-Sensor for the determination of the leakage rate and process control
During many processes like vacuum processes, polyimide cure, debindering or ceramics it is important to know whether residual oxygen is still present in the furnace. With the oxygen sensor evidence can be provided that the process can run off safely. The signal of the oxygen sensor offers the possibility to set process specific limits, with which actions can be initiated, e.g. the termination of heating procedure or the discharging of emergency purging.
As an analysis tool a Stange controller can be used or also any other suitable display. The batch comparison function of the Stange software ECS-2000 ensures a simple checking of the continuity of the sensor signal of an unmodified processes. The signal of the oxygen sensor is pressure independent!

Oxygen Sensor

New, revolutionary measuring procedure with a modified zircon measuring cell (heated), attached online to the reactor. The measuring cell is equipped with an oxygen pump and provides permanently an exchange of the atmosphere at the measuring cell. The oxygen pump works according to a physical principle similarly the heat convection.
  • no wear, insensitive to contamination
  • vacuum proven
  • no exhaust gas contact with the sensor
  • pressure-insensitive measurement principle
  • Maximum over pressure at the sensor: 10bar
  • Minimum pressure at the sensor: 10-7 mbar
  • Reaction, depending on installation < 20s
  • Measuring ranges: 0 to 100 Vol% O2 or 0 to <= 100ppm O2



  • About us ▾
  • Products ▾
    • Semiconductor Manufacturing
    • Semiconductor Furnaces ▸
    • Factory Automation ▸
    • Solar cell-Manufacturing
    • Equipment for Solar Applications ▸
    • LCD-Manufacturing
    • Machines for manufacturing LCD, OLED & DSSC ▸
    • Fuel cell & battery-Manufacturing
    • Industrial furnaces
    • Thermal treatment of steel ▸
    • Thermal treatment of glass & ceramic ▸
    • Gas technology
    • Gas Generators ▸
    • Exhaust Gas Cleaning Systems ▸
    • Gas sensors ▸
    • Furnace accessories
  • Applications ▾
    • Semiconductor Manufacturing
    • Thermal Processes ▸
    • Solar cell-Manufacturing
    • LCD-Manufacturing
    • Manufacturing LCD, OLED & DSSC ▸
    • Fuel Cell & Battery Manufacturing
    • Industrial furnaces
    • Thermal treatment of steel ▸
    • Thermal treatment of glass & ceramic ▸
    • Gas technology
    • Gas generators ▸
    • Exhaust Gas Cleaning Systems ▸
    • Gas sensors ▸
    • Furnace accessories
  • Language ▾

Read this article to learn about 3 Methods of Measuring Dissolved Oxygen!

1. Chemical Method:

Oxygen Measurement

The determination of DO concentration in pure water or in waste water involves the addition of known excess quantities of a standard solution of reduced ion (such as ferrous or manganous), followed by a back titration of the excess with a known standard oxidizing agent.

Among these methods, Winkler’s method was widely used until the development of the DO probe. In principle, this method involves the formation of a precipitate of manganous hydroxide. This is oxidized to MnO(OH)2 by oxygen in the solution, which in turn oxidizes iodine. This liberated iodine is estimated by back titration with standard Na2S2O3 solution.

ADVERTISEMENTS:

From these results, DO concentration in ppm can be determined using the following relation:

Oxygen Measurement

2. Physical Method:

This method makes use of the oxygen probe which measures DO concentration in the solution directly. The partial pressure of oxygen in a mixture of gases or in an aqueous liquid in dissolved form can be monitored by use of specially designed galvanic or amperometric electrodes or probes.

An oxygen electrode, in principle, is a device that produces an electric current which is proportional to the DO in the liquid medium in which the probe (electrode) is placed. Various types of DO electrodes are in use to determine DO concentration in fermentation broths and other biochemical reactions. On the basis of their operational characteristics, these oxygen electrodes may be classified as in Table 5.9.

Measurement

Some of these electrodes are steam sterilizable, while many are not. The most popular oxygen electrodes used for the respiratory measurements and DO concentration measurements in microbial and medical engineering systems is membrane-covered electrodes. In determining DO concentration, the DO probe is placed in an electrical circuit which functions in the following most widely used way.

a. It imposes a potential difference between the oxygen electrode and some reference anode, which is usually a calomel half-cell or Silver-Silver chloride half-cell.

b. It measures the current passing through the electrode.

Typical examples of membrane-covered polarographic and galvanic type of DO probes are shown in the literature. Basically, the current output of the probe depends on the tension of oxygen that participates in the electrochemical reaction. It is obvious that the response time of the electrode depends on the membrane type and its thickness. It is determined by the time required for equilibrium.

Oxygen gradient will be established in the captive electrolyte film and the membrane following a change in oxygen level. The average 97.5% response time for a 1-mil Teflon membrane electrode is 10 s, which for a 1-mil polypropylene is closer to 40s. Table 5.9 provides the typical 97.5% response times obtained with several oxygen electrodes having membranes of differing composition and thickness.

Electrode output and response time as a function of cathode membrane and membrane thickness are given. It was shown earlier that the magnitude of the current produced by the electrode is directly proportional to the oxygen concentration, provided D remains constant.

The current produced when the electrode is exposed to oxygen is actually a function of the individual electrode and its functional state and environmental conditions (e.g., temperature, ionic strength of the liquid, etc.). Consequently, it is essential to calibrate the ammeter or recorder response by exposure to known concentrations of dissolved oxygen.

Two conventional reference concentrations of oxygen are selected to calibrate a DO electrode, since the current output by the electrode is usually linear with oxygen concentration. The most convenient oxygen concentrations to use are those of air-saturated solution and a solution with zero oxygen content. The former is easily prepared by the continuous gentle bubbling of air through the buffer in use at the desired working temperature.

Solutions with zero oxygen-content may be prepared by the following methods:

1. Dithionite method, which includes the following steps:

Span control of the amplifier/ recorder is adjusted to 95-100% of full-scale deflection for the electrode immersed in an air-saturated solution. Next, sodium dithionite solution prepared by injecting saturated solution of Na2S406 (freshly prepared, pH 7.5-8, in absence of oxygen) is added to the reaction liquid in 1: 30 v/v ratio, and a new value in the recorder is noted (usually 0-1% of the full-scale deflection).

It is due to a residual current output of the electrode in the absence of oxygen. The addition of more dithionite should produce no further change, and thus it is calibrated. The demerit of this method is that prolonged exposure to dithionite causes poisoning of the electrode. Therefore, the electrode must be removed from the dithionite solution immediately after the measurement.

2. Nitrogen discharging method:

ADVERTISEMENTS:

In which a standard buffer solution is equilibrated with nitrogen by discharging the gas in it. Nitrogen discharge drives out any oxygen present in the buffer, leading to a buffer with zero oxygen content.

Therefore, by measuring the current output by placing the oxygen electrode into solutions of zero oxygen content and in solutions saturated with oxygen, respectively, a standard curve is plotted which gives the relation between current/voltage output of the electrode and DO concentration in the liquid.

By measuring the current/voltage output of the calibrated electrode in an unknown solution, its DO concentration can be known from this standard curve. After calibration, the probe is sterilized (if required) and is put into the bio-reaction liquid asceptically or gas mixture in which oxygen is to be measured.

In medical engineering, a probe that was used to monitor oxygen tension in anaesthetic circuits (modification of Meckereth electrode) utilizes a silver cathode, lead anode, and potassium hydroxide electrolyte. Oxygen used to be admitted to the electrode through a teflon membrane, which is pervious to gas, but not to the electrolyte. Oxygen is reduced at the cathode to form a hydroxyl ion in a reaction catalyzed by the silver.

These ions combine with lead at the anode to form lead hydroxide. The electron flow from the lead to the silver cathode through a micro-ammeter is a measure of the rate at which the reaction proceeds. Hence, the meter reading depends on the rate at which the external tension forces oxygen to diffuse through the membrane and contact the silver electrode.

These probes are rugged, operable in any position, unaffected by humidity, and self-contained (requiring no amplifier, pump, or heat source). They are compact— a probe of this type has been used by mounting it on the tip of a cardiac catheter for in vivo recording of blood oxygen tensions. Their readout can be made linear and accurate to within 5% of full scale.

The reading is not altered by the addition of compounds like halothane, methoxyflurane, or ether to an atmosphere of 20% oxygen and 80% helium. On the other hand, the probes are relatively expensive and short-lived. A commercial model, however, is warranted for 80,000 hours. At 21% oxygen, this would give a life expectancy of 80,000/21 = 3810 h, or approximately 23 weeks. Their response is slow, varying from one to several seconds. Carbon dioxide shows response time and in continuous exposure shortens probe life.

An oxygen probe employing a zirconium oxide galvanic electrode (similar to that described by Elliot and his associates) is commercially available. Its response time is so rapid (less than 100 ms) that the effect of pulsatile blood flows is detectable in the recording of oxygen tensions during a single expiration. C02 has no effect on the probe output, but the presence of gaseous anaesthetic agents causes gross inaccuracy. This monitor has a built-in heater, because the probe must be operated at 8.50°C. It also incorporates a vacuum pump and an amplifier.

3. Biological Method:

Oxygen

ADVERTISEMENTS:

In this method, a highly selective flow system has been used by coupling immobilized whole bio-cells or enzymes with electrochemical sensors. In principle, two types of biosensors have been reported. The first type consists of enzyme or bio-cell electrodes in which immobilized whole bio-cell or enzyme is in direct contact with the potentiometric or amperometric sensor.

Oxygen Measurement Instrument

In the second type, the enzyme, or whole cell, immobilized on a solid support (bioreactor) is incorporated in the flow line into which the analyte is injected. The product generated is detected and measured with an electrochemical sensor downstream. A bio-electrochemical system with immobilized whole bio-cell or enzyme has been applied to flow injection analysis to monitor oxygen.

For glucose determination in flow systems, glucose oxidase has been frequently employed because of its high selectivity for (3-D-glucose, which is oxidized producing H2O2. The H2O2 produced enzymatically can be monitored electrochemically. As anoxic oxidation of the hydrogen peroxide is irreversible, calibration curves for glucose with glucose electrodes are shown in Table 5.10.

Measuring Oxygen Level

Related Articles: